Frequency of pat testing: Inspection Test Frequency
The Inspection Test Frequency carries 14 published figures read from 6 sources' own pages; the 7 published figures given by environment run from 1 to 5 year, read 24 October 2026.
- 41 to 3
- 13 to 4
- 84 to 6
- 6 to 7
- 7 to 9
- 19 to 10
Bands
| Bucket | Value |
|---|---|
| 1 to 3 | 4 figures |
| 3 to 4 | 1 figure |
| 4 to 6 | 8 figures |
| 6 to 7 | 0 figures |
| 7 to 9 | 0 figures |
| 9 to 10 | 1 figure |
6 of the 22 named sources read in full publish a figure; 16 publish none, read 24 October 2026.
By environment and equipment-class and tenure
| Breakdown | Median | Range | Sources |
|---|---|---|---|
| environmentschools | 5year | 5 to 5year | 1 |
| environmentcare-homes | 5year | 5 to 5year | 1 |
| environmentleisure | 3year | 3 to 3year | 1 |
| environmentindustrial | 3month | 3 to 3month | 1 |
| environmentconstruction | 3month | 3 to 3month | 2 |
| environmentoffice | 4year | 4 to 4year | 2 |
| environmenthotels-schools | 2year | 2 to 2year | 1 |
| environmentswimming-pool | 1year | 1 to 1year | 1 |
| equipment-classhandheld | 48month | 48 to 48month | 1 |
| tenurerented | 2year | 2 to 2year | 1 |
| tenureprivate-rented | 5year | 2 to 5year | 3 |
| tenureowner-occupied | 10year | 10 to 10year | 1 |
| tenureprivate-rented-scotland | 5year | 5 to 5year | 1 |
| tenuresocial-housing | 5year | 5 to 5year | 1 |
Every figure, with its source
One row per published figure: the figure as the source's own page publishes it, the page, and the day it was read. A figure that is not on a page we read is not on this one.
The sentence each figure was read from (18)
- How Often Should PAT Testing Be Done? Full UK Frequency Table, read 2026-10-24:
Handheld and portable items (kettles, desk fans, phone chargers) fall on a 24–48 month cycle depending on class.
- Electrical Installation Regulations UK: BS 7671 Explained, read 2026-10-24:
Homeowners should get an EICR every ten years or when moving into an older property where the installation history is unknown, giving you a detailed record of any faults that need fixing.
- Commercial EICR Frequency London, read 2026-10-24:
Schools: 5 years maximum, with annual visual inspection.
- Commercial EICR Frequency London, read 2026-10-24:
Care homes and supported living: 5 years EICR plus annual visual.
- Electrical Installation Regulations UK: BS 7671 Explained, read 2026-10-24:
Landlords must arrange an Electrical Installation Condition Report (EICR) at least every five years for rental properties, and you should get one every ten years for your own home.
- EICR Frequency of Inspections - Pro Certs Software Ltd, read 2026-10-24:
The maximum interval between EICRs for a domestic rental property is 5 years, however the electrician may specify that the installation is next inspected in less than 5 years depending on the results of their inspection, measured test results and/or non-compliances.
- How Often Should PAT Testing Be Done? Full UK Frequency Table, read 2026-10-24:
In Scotland, Repairing Standard guidance D.56 includes appliance inspection/testing before first letting and at intervals no greater than five years; a new tenancy alone does not require a repeat when the inspection remains current.
- How Often Should PAT Testing Be Done? Full UK Frequency Table, read 2026-10-24:
In England, distinguish private renting from social housing: the regulations require fixed-installation inspections, and the 2025 extension also requires social landlords to arrange checks of supplied electrical equipment at least every five years.
- How Often Should PAT Testing Be Done? Full UK Frequency Table, read 2026-10-24:
Yes — a desktop PC in a typical UK office doesn't need combined testing for up to four years.
- HSE PAT Testing Guidance: Requirements, Frequency & Records, read 2026-10-24:
Low-risk offices (IT equipment) None required Every 2-4 years Every 2-4 years
- Commercial EICR Frequency London, read 2026-10-24:
The annual interval reflects the consequence of failure. Gyms and dry leisure (no pool): 3 years standard.
- Commercial EICR Frequency London, read 2026-10-24:
Heavier-duty industrial with significant motor load or harsh environment (chemical, foundry, food processing) can pull to annual. Construction sites: 3 months.
- How Often Should PAT Testing Be Done? Full UK Frequency Table, read 2026-10-24:
The IET Code of Practice sets out intervals from 3 months (construction) up to 60 months (office IT) depending on environment and appliance.
- HSE PAT Testing Guidance: Requirements, Frequency & Records, read 2026-10-24:
Hotels and schools Weekly/monthly Every 1-2 years Every 1-2 years Construction sites Daily Every 3 months Every 3 months
- How Often Should PAT Testing Be Done? Full UK Frequency Table, read 2026-10-24:
The widely accepted standard is every 2 years, or at every change of tenancy (whichever is sooner).
- How Often Should PAT Testing Be Done? Full UK Frequency Table, read 2026-10-24:
For standard buy-to-let residential rentals, PAT testing every tenancy change or every 2 years (whichever is sooner) is the widely accepted approach.
- HSE PAT Testing Guidance: Requirements, Frequency & Records, read 2026-10-24:
Hotels and schools Weekly/monthly Every 1-2 years Every 1-2 years
- Swimming Pool Zones: Zone 1 = 2m, Zone 2 = 3.5m, read 2026-10-24:
The recommended EICR interval for a swimming pool is typically 1 year for commercial pools and 3 years for domestic pools, though the inspector should assess based on the condition and usage.
Read in full, publishes no figure
16 named sources were read in full on the dates shown and print no usable figure. They are counted, never filled in.
- Repairing Standard: statutory guidance for private landlords - gov.scot, read 2026-09-12: read in full and no accepted figure on the page
- Private renting: Your landlord's safety responsibilities - GOV.UK, read 2026-09-12: every candidate on the page was refused
- Maintaining electrical equipment safety - HSE, read 2026-10-17: read in full and no accepted figure on the page
- Maintaining portable electric equipment in low-risk environments - HSE, read 2026-09-12: read in full and no accepted figure on the page
- PAT (Portable appliance testing) - HSE's answers to popular questions, read 2026-09-11: read in full and no accepted figure on the page
- Maintaining portable electrical equipment - HSE, read 2026-09-12: read in full and no accepted figure on the page
- hse.gov.uk, read 2026-09-12: read in full and no accepted figure on the page
- Getting repairs done as a private tenant - mygov.scot, read 2026-10-10: read in full and no accepted figure on the page
- PAT Testing Frequency: How Often Should It Be Done?, read 2026-09-12: read in full and no accepted figure on the page
- housingandpropertychamber.scot, read 2026-09-12: read in full and no accepted figure on the page
- PAT Testing Frequency Guide, read 2026-10-24: read in full and no accepted figure on the page
- PAT Testing Frequency: Recommended Intervals by Appliance Type, read 2026-09-19: every candidate on the page was refused
- INDG236: Maintaining Portable Electrical Equipment, read 2026-09-12: read in full and no accepted figure on the page
- aber.ac.uk, read 2026-09-20: read in full and no accepted figure on the page
- leia.co.uk, read 2026-09-12: read in full and no accepted figure on the page
- theiet.org, read 2026-10-25: read in full and no accepted figure on the page
Methodology
Every row is a verbatim sentence read from the named source's own page through our fetch service on the date shown, hash-pinned to the stored read (the sha of the page's visible text; the raw page is mirrored to R2).
6 of the 22 named sources that could be read published a usable figure; 16 published none and are recorded as not published, never filled in; 0 could not be read (blocked, dead or unreachable) and count nowhere.
The headline figures (median, minimum, maximum, quartiles) are over ONE figure per source for each breakdown it prices, in year (a source's median where its page yielded several accepted sentences for one breakdown), so a page that gives figures for several breakdowns gives one for each and N counts 14 figures, never sentences; 53 candidate sentence(s) were refused by a reviewer with the reason recorded.
The fuller derivation this dataset is chartered to grow into (not yet what the figures above are; they are each source's own published figure as read): Two intervals that nobody publishes as one answer, each labelled with whether it is LAW or GUIDANCE.
For portable appliances: the initial interval by equipment class and environment (hand-held against stationary, office against construction site against equipment hire), from HSE's own guidance - which says explicitly that no fixed interval is required by law and that the suggested tables are suggestions.
For fixed installations: the maximum period between inspections by tenure and premises type (private rented 5 years by statute in all four nations, owner-occupied 10 years by guidance, HMO, commercial, industrial, caravan park, swimming pool), from the statute where a statute sets it and from BS 7671 / IET guidance where it does not.
The derivation is the gap: how often the internet's stated interval is a guidance figure being repeated as if it were law.
53 candidate sentences on these pages were refused by a reviewer; each refusal and its reason is recorded in the review ledger.
Sources (22)
- Repairing Standard: statutory guidance for private landlords - gov.scot(the publisher's own terms; quoted for reporting and comment)
- Private renting: Your landlord's safety responsibilities - GOV.UK(the publisher's own terms; quoted for reporting and comment)
- Maintaining electrical equipment safety - HSE(the publisher's own terms; quoted for reporting and comment)
- Maintaining portable electric equipment in low-risk environments - HSE(the publisher's own terms; quoted for reporting and comment)
- PAT (Portable appliance testing) - HSE's answers to popular questions(the publisher's own terms; quoted for reporting and comment)
- Maintaining portable electrical equipment - HSE(the publisher's own terms; quoted for reporting and comment)
- hse.gov.uk(the publisher's own terms; quoted for reporting and comment)
- Getting repairs done as a private tenant - mygov.scot(the publisher's own terms; quoted for reporting and comment)
- PAT Testing Frequency: How Often Should It Be Done?(the publisher's own terms; quoted for reporting and comment)
- Commercial EICR Frequency London(the publisher's own terms; quoted for reporting and comment)
- housingandpropertychamber.scot(the publisher's own terms; quoted for reporting and comment)
- PAT Testing Frequency Guide(the publisher's own terms; quoted for reporting and comment)
- How Often Should PAT Testing Be Done? Full UK Frequency Table(the publisher's own terms; quoted for reporting and comment)
- PAT Testing Frequency: Recommended Intervals by Appliance Type(the publisher's own terms; quoted for reporting and comment)
- INDG236: Maintaining Portable Electrical Equipment(the publisher's own terms; quoted for reporting and comment)
- aber.ac.uk(the publisher's own terms; quoted for reporting and comment)
- Swimming Pool Zones: Zone 1 = 2m, Zone 2 = 3.5m(the publisher's own terms; quoted for reporting and comment)
- Electrical Installation Regulations UK: BS 7671 Explained(the publisher's own terms; quoted for reporting and comment)
- HSE PAT Testing Guidance: Requirements, Frequency & Records(the publisher's own terms; quoted for reporting and comment)
- leia.co.uk(the publisher's own terms; quoted for reporting and comment)
- EICR Frequency of Inspections - Pro Certs Software Ltd(the publisher's own terms; quoted for reporting and comment)
- theiet.org(the publisher's own terms; quoted for reporting and comment)
Cite or embed this figure
Cite or embed this figure
The Inspection Test Frequency carries 14 published figures read from 6 sources' own pages; the 7 published figures given by environment run from 1 to 5 year, read 24 October 2026.
6 of the 22 named sources read in full publish a figure; 16 publish none, read 24 October 2026.
Inspection Test Frequency, environment schools: median 5 year across 1 source, read 24 October 2026.
Inspection Test Frequency, environment care-homes: median 5 year across 1 source, read 24 October 2026.
Inspection Test Frequency, environment leisure: median 3 year across 1 source, read 24 October 2026.
Inspection Test Frequency, environment industrial: median 3 month across 1 source, read 24 October 2026.
Inspection Test Frequency, environment construction: median 3 month across 2 sources, read 24 October 2026.
Inspection Test Frequency, environment office: median 4 year across 2 sources, read 24 October 2026.
Inspection Test Frequency, environment hotels-schools: median 2 year across 1 source, read 24 October 2026.
Inspection Test Frequency, environment swimming-pool: median 1 year across 1 source, read 24 October 2026.
Inspection Test Frequency, equipment-class handheld: median 48 month across 1 source, read 24 October 2026.
Inspection Test Frequency, tenure rented: median 2 year across 1 source, read 24 October 2026.
Inspection Test Frequency, tenure private-rented: median 5 year across 3 sources, read 24 October 2026.
Inspection Test Frequency, tenure owner-occupied: median 10 year across 1 source, read 24 October 2026.
Inspection Test Frequency, tenure private-rented-scotland: median 5 year across 1 source, read 24 October 2026.
Inspection Test Frequency, tenure social-housing: median 5 year across 1 source, read 24 October 2026.
Cite as: "Asbestos Survey Cost Inspection Test Frequency", updated 2026-10-26, https://asbestossurveycost.co.uk/datasets/inspection-test-frequency/.
Download the CSV (18 rows, computed 2026-10-26)