Dry chemical fire extinguisher (2 figures)

The Extinguisher Class and Standard carries 4 published figures read from 2 sources' own pages, from 5 to 10 year, read 24 October 2026.

5 to 10 year Range of the published figures 4 published figures, not one market: read the rows
2 Published figures from 2 source pages, read 25 Oct 2026
2 of 12 Sources read that publish one 17% publish a figure at all
  1. OSHA 1910.157 standard text10 year
  2. OSHA 1910.157 standard text6 year
  3. MCA Marine Guidance Note 276: maintenance of portable fire extinguishers5 year
  4. OSHA 1910.157 standard text5 year
Every published figure, highest first.
Table view
RowValue
OSHA 1910.157 standard text10 year
OSHA 1910.157 standard text6 year
MCA Marine Guidance Note 276: maintenance of portable fire extinguishers5 year
OSHA 1910.157 standard text5 year

2 of the 12 named sources read in full publish a figure; 10 publish none, read 24 October 2026.

By jurisdiction

BreakdownMedianRangeSources
jurisdictionGB5year5 to 5year1
jurisdictionUS6year6 to 6year1

Every figure, with its source

One row per published figure: the figure as the source's own page publishes it, the page, and the day it was read. A figure that is not on a page we read is not on this one.

The sentence each figure was read from (4)
  • OSHA 1910.157 standard text, read 2026-10-24: Nitrogen cylinders which comply with 49 CFR 173.34(e)(15) may be hydrostatically tested every 10 years.
  • OSHA 1910.157 standard text, read 2026-10-24: The employer shall assure that stored pressure dry chemical extinguishers that require a 12-year hydrostatic test are emptied and subjected to applicable maintenance procedures every 6 years.
  • MCA Marine Guidance Note 276: maintenance of portable fire extinguishers, read 2026-10-24: Type of portable extinguisher Basic service Extended service (test discharge) Overhaul (hydraulic test) Water, foam, & water based Every year Every 5 years Every 10 yearsc
  • OSHA 1910.157 standard text, read 2026-10-24: The employer shall assure that carbon dioxide extinguishers and nitrogen or carbon dioxide cylinders used with wheeled extinguishers are tested every 5 years at 5/3 of the service pressure as stamped into the cylinder.

Read in full, publishes no figure

10 named sources were read in full on the dates shown and print no usable figure. They are counted, never filled in.

Methodology

Every row is a verbatim sentence read from the named source's own page through our fetch service on the date shown, hash-pinned to the stored read (the sha of the page's visible text; the raw page is mirrored to R2).

2 of the 12 named sources that could be read published a usable figure; 10 published none and are recorded as not published, never filled in; 4 could not be read (blocked, dead or unreachable) and count nowhere.

The headline figures (median, minimum, maximum, quartiles) are over ONE figure per source in year (a source's median where its page yielded several accepted sentences), so N counts sources, never sentences; 47 candidate sentence(s) were refused by a reviewer with the reason recorded.

The fuller derivation this dataset is chartered to grow into (not yet what the figures above are; they are each source's own published figure as read): one row per extinguishing agent per jurisdiction, joining what nobody publishes in one place: the fire classes the agent is rated for, the colour band or label the jurisdiction's standard gives it (BS EN 3-7's signal-red body with a >=5% second-colour zone in GB, NFPA 10's letter-and-pictograph label in the US), the mounting height and travel distance the regulator sets (OSHA's 5ft / 3.5ft by weight and 4in floor clearance; the UK's siting practice), the inspection, service, extended-service and hydrostatic-test intervals with their source clause, and the SAME-AGENT-DIFFERENT-NAME map (UK 'wet chemical' = US Class K; UK 'powder' = US 'dry chemical'), which is the single figure the two highest-volume keyword blocks in this venture are both asking for and which no authority publishes because each authority only knows its own regime; changed-since on every standard revision and rate-year turn

47 candidate sentences on these pages were refused by a reviewer; each refusal and its reason is recorded in the review ledger.

Sources (16)
Cite or embed this figure

Cite or embed this figure

The Extinguisher Class and Standard carries 4 published figures read from 2 sources' own pages, from 5 to 10 year, read 24 October 2026.

2 of the 12 named sources read in full publish a figure; 10 publish none, read 24 October 2026.

Extinguisher Class and Standard, jurisdiction GB: median 5 year across 1 source, read 24 October 2026.

Extinguisher Class and Standard, jurisdiction US: median 6 year across 1 source, read 24 October 2026.

Cite as: "Asbestos Survey Cost Extinguisher Class and Standard", updated 2026-10-25, https://asbestossurveycost.co.uk/datasets/extinguisher-class-and-standard/.

Embed this figure (plain HTML, no scripts)

5 to 10 year

2 published figures, Extinguisher Class and Standard, across 2 sources, read 24 October 2026

Source: Asbestos Survey Cost Extinguisher Class and Standard

Download the CSV (4 rows, computed 2026-10-25)

Get asbestos quotesSearch the register