Fire hydrant system: hydrants, dry and wet risers, and what the owner has to do

Hydrants and risers are firefighting infrastructure rather than firefighting equipment: they exist so that the fire and rescue service can get water to a fire without running hose up a staircase. A building owner never uses them, and is entirely responsible for the ones on their premises still working when somebody else needs them.

Get asbestos quotes

Hydrants

A hydrant is a connection to the water main, usually below a hinged cover in the street or in a private road, marked with a yellow hydrant sign giving the size of the main and the distance to the hydrant. Crews connect a standpipe to it and take water from there. Private hydrants on a site are the site owner's to maintain, which includes keeping them accessible, keeping the marker plate visible and having them tested.

Dry risers and the dry riser landing valve

A dry riser is an empty pipe running up through a building with an inlet at ground level and landing valves on each floor. The fire service pumps water into the inlet and takes it out at the floor they need. It is used in buildings above a certain height where running hose from a pump would take too long. Everything about it is dormant until the day it is used, which is why it is tested.

The wet riser system

A wet riser is permanently charged with water, fed by a pump and tank, and is used in taller buildings where a fire service pump could not deliver adequate pressure to the top. It carries all the maintenance obligations of a pumped water system: pumps, tanks, pressure, power supplies and the valves themselves, and it fails in ways a dry riser cannot.

What the owner has to do, including fire hydrant testing

Keep inlets and landing valves accessible and unobstructed, keep the cabinets closed and undamaged, arrange periodic testing including a wet test of the riser at intervals, and act on the results. Vandalised inlet cabinets and blocked hydrant covers are common and both waste minutes at the worst possible time. These are fire safety measures under the general duty to maintain like anything else.

The dry riser box, and the dry riser door that has to open

At each landing the outlet sits in a cabinet with a breakable glass or a standard key, and the inlet at ground level sits in its own box where the brigade connects. Both are simple and both fail in the same dull ways: a door painted shut, a lock changed when the building was refurbished so the standard key no longer works, a cabinet with a cupboard built in front of it, and glass broken long ago and never replaced. The annual test and the six monthly visual check exist to catch exactly these, and the inspection record should name the landing rather than say the system passed, because a system is only as good as the one door somebody cannot open.

Questions people ask about fire hydrant system

Wet riser vs dry riser: what is the difference?

A dry riser is an empty pipe the fire service pumps water into from ground level. A wet riser is permanently charged by its own pump and tank, used in taller buildings where a pump could not reach the top.

Who maintains a fire hydrant?

Public hydrants are maintained through the water undertaker and fire authority arrangements. Private hydrants on a site are the site owner's responsibility, including access, marker plates and testing.

Do building occupants ever use risers?

No. Risers and hydrants are firefighting infrastructure for the fire and rescue service. The occupier's duty is to keep them accessible, maintained and tested.

Who provides the fire hydrant hose?

The attending crew. A hydrant is a water supply point with no hose or equipment on it, which is why what the building owes is access and a clear, signed location rather than kit.

What is a fire hose cabinet for, and should the occupants use it?

It holds a hose reel connected to the building's water supply, and it is equipment for trained people rather than a general amenity. Reels were fitted very widely in older commercial buildings and many are now isolated or removed, because an untrained person with a hose tends to stay and fight a fire they should have left. If a building still has them they are part of the firefighting equipment the assessment has to justify and the maintenance regime has to cover, which means an annual service and a record. If the assessment does not call for them, the honest answer is often to remove them rather than to keep testing them.

Sources